9. Disconnect the Fan Wire
Harness at the back as well.
Figure 10.6
11. Remove the Blowers from
the Fireplace.
Figure 10.8
13. At this point, if you want to test the Blower operation, do so with
the Gas Supply turned off or disconnected. To test the Blower
operation, you will need to re-connect the electrical supply
temporarily. Disconnect the Electrical Supply after testing the
Blowers.
Figure 10.10
XG0523 - 170223
10. Remove 3 screws that
mount each fan in place.
Figure 10.7
12. Install both new Blowers.
Secure the Wire Harness
with the Zip Straps.
Figure 10.9
Figure 10.11
14. Re-install the Outer Shell Rear panel.
15. You will need to replace the Flue Collar Plate Gasket prior to re-
installation into the cavity.
16. Replace the Flue Connector Plate Gasket.
17. Re-install the unit into the Cavity. See the section on Vent
Connections.
18. Re-install the Face Plate Panels. See the section on Setup.
19. Re-connect the Electrical Supply.
Operation
Figure 10.12
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

30fidlil-01

Table of Contents