Section 7: Cleaning; Cleaning; Vent Maintenance / Inspection - Montigo 30FIDNIL-01 Installation & Maintenance Manual

I series inserts indoor gas fireplace
Hide thumbs Also See for 30FIDNIL-01:
Table of Contents

Advertisement

Section 7: Cleaning

Cleaning

When the fireplace is first activated, there may be some smoke and a
visible film may be left on the glass. This is a normal condition, and is
the result of burning of protective coatings on new metal.
• Glass must be cleaned periodically to remove any film (which is
a normal by-product of combustion) which may be visible. Film
can easily be removed by removing the door. Handle the door
carefully, and clean it with non-abrasive, non-ammonia based
glass cleaners. One of the most effective products is Kel-Kem.
• During the initial firing, Silicone seals will "off gas", leaving a
visual deposit of a white substance on combustion chamber
walls. This can easily be removed using normal household
products.
• Use a vacuum cleaner or whisk broom to keep the control
compartment, burner, and firebox free from dust and lint.
NOTICE
Do not use ammonia or abrasive cleaners on the glass, they will
permanently etch the surface. Use an approved gas fireplace cleaner
such as Kel-Kem or White off.
46
Vent Maintenance / Inspection
Part of the annual maintenance on this appliance should include
a thorough inspection of the entire Venting and Termination. Vent
inspection should include:
Roofing Inspection and repair should only be performed by a
licensed and qualified roofing professional.
• CONNECTION TO THE FIREPLACE
• Make sure that the attachment of the venting to the top of the
Appliance is tight, secure and that no corrosion has affected
the venting's integrity.
• Make sure that both vents (incoming & outgoing) are secure
and that these flexible liners have not been kinked, restricted
or damaged in any way.
• Make sure there are no "dips" in the venting. Condensation can
collect and affect the performance of the Fireplace if the venting
is not vertical in all areas.
• ROOF TERMINATION
• Make sure that all sealing materials are in good condition and
that there is no opportunity for moisture to access the building.
• Make sure there are no signs of corrosion to the Vent Termination
or Roof Flashing
• Make sure there are no signs of intrusion by any birds or pests of
any kind. Make sure animals have not built any nests anywhere
in the vicinity of the Vent Termination.
• CONNECTION TO THE VENT TERMINATION
• If you have to re-seal a Vent Termination or Roof Flashing, firstly
make sure the Venting is secure to the Termination or Vent
Adaptor. Make sure there are no signs of corrosion anywhere
in the venting system.