Montigo 30FIDNIL-01 Installation & Maintenance Manual page 9

I series inserts indoor gas fireplace
Hide thumbs Also See for 30FIDNIL-01:
Table of Contents

Advertisement

Mantel
Clearances Cont.
10"14"18"24"26" 30"34"38"
39"
37"
35"
33"
31"
29"
27"
25"
23"
21"
19"
17"
10"
254
10"
MAX
Max
17"
30FID 16" Min.
432
34FID 23" Min.
Minimum
Figure 2.2 Install clearances
Non Combustible Board Install
Non combustible facing
Non-combustible facing
materials must be used above
materials must be used above
the unit, up to the minimum
the unit up to minimum
required mantel height clearance
required mantel height
and for the entire width of the
clearance and for the entire
fireplace opening. This includes
width of the fireplace opening.
all types of possible installations.
This includes all types of
possible installations.
Wall face
Wall Face
Figure 2.3 Non Combustible Board Install
XG0528 - 170223
17"
432
Faceplate
Allowable
Allowable
Mantel
mantel area
Area
Gas Insert
Gas Insert
Section 3: Venting
Hearth Protection
Not Required
30FID units use 3"x3" venting. 34FID units use 3"x4" venting
Termination
46DVA-VCH, Duravent Vertical, High Wind Termination
Adaptor
46DVA-CT, Duravent 3" x 3" to 4" x 5 5/8" Co-linear to Co--axial Adaptor
Connectors
4DFA-FC, Duravent 4" Flex Liner Coupling
Mantle
Mantle
3DFA-FC, Duravent 3" Flex Liner Coupling
Side wall
Side Wall
Venting
4" Flex Liner and 3" Flex Liner
Installation
10"
254
Side Wall
8"
203
NOTICE
10"14"18"24"26" 30"34"38"
39"
37"
35"
33"
31"
29"
27"
25"
23"
21"
Allowable
19"
Mantel
10"
Area
254
Max
Figure 3.0 Approved Vent Components
9