WARNING
The use of the fans when the Cool Wall Release OR Cool Wall
Advantage system is used will result in significantly higher wall
temperatures. These higher temperatures can negatively impact
the finished wall surface, art, and or mounted TV. Therefore,
Montigo STRONGLY RECOMMENDS that fans be disconnected
when the Cool Wall Release OR Cool Wall Advantage system is used.
This can be done through the remote control (See instructions)
or by disconnecting the fan harness. Montigo is NOT responsible
for damage to facing materials, and items placed above the
fireplace (eg. TV, artwork)

FULL LOAD VERSIONS:

Disable fans via remote
1. Turn the fireplace on, turn fans to off setting.
2. Partially take out one battery.
3. Hold both the Mode AND On/Off button.
4. Insert battery (while still holding the two
buttons), then release Mode button (keep
On/Off pressed).
5. Cycle through modes with Mode button until
you get to fan setting, with Down button set
fan function from Set to Clr.
6. Release On/Off button, turn the fireplace on.
There will be now be no fan mode on remote.
BASIC VERSIONS (IF OPTIONAL
FAN KIT ALREADY INSTALLED):
Disable fans via harness
1. Unplug the fan
harness that
connects power to
the speed control.