Fault trip memory ... The cause of the trip is saved in parameters P67 to P70.
The details on the latest trip and the three prior trips is saved even if the
power is turned OFF. (The details of the shipment inspection are saved
when the unit is shipped.)
Display
SC1
SC2
SC3
OC1
OC2
OC3
OU1
OU2
OU3
LU
OL
Downloaded from
www.Manualslib.com
Individual Details and Remedies
for Fault Trips
Details and cause of faults
Instantaneous overcurrent
during acceleration or abnormal
heating of heat sink fins
Instantaneous overcurrent
during constant speed or
abnormal heating of heat sink
fins
Instantaneous overcurrent
during deceleration or abnormal
heating of heat sink fins
Overcurrent during acceleration
Overcurrent during constant
speed
Overcurrent during deceleration
Excessive internal DC voltage
during acceleration
Excessive internal DC voltage
during constant speed
Excessive internal DC voltage
during deceleration
Power supply voltage drops to
less than 85% of rating
An output current exceeding
125% of the electronic thermal
setting current or 140% or more
of the inverter rated current
occurs for more than 1 minute
manuals search engine
Remedies
Check for an output short-circuit
or ground fault
Check the ambient temperature
and fan operation
Increase the acceleration time
Check for output short-circuit
and ground fault
Check ambient temperature
and fan operation
Eliminate excessive changes in
load
Check for output short-circuit
and ground fault
Check ambient temperature
and fan operation
Increase the deceleration time
Check for an open output phase
Increase the acceleration time
Adjust the torque boost level
Check for an open output phase
Eliminate excessive changes in
load
Check for an open output phase
Increase the deceleration time
Increase the acceleration time
Eliminate excessive changes in
load
Increase the deceleration time
Measure the power supply
voltage
Consider using the
instantaneous power failure
restart function
Check the electronic thermal
setting current
Check and adjust the torque
boost level
Reduce the load
74