Panasonic VF0 Series Instruction Manual page 52

Compact inverter 400v class
Hide thumbs Also See for VF0 Series:
Table of Contents

Advertisement

2nd BASE FREQUENCY (Parameter P41)
Used to set the 2nd base frequency selected with
2nd characteristics select switch.
Data setting range
Note)
2nd TORQUE BOOST LEVEL (Parameter P42)
Used to set the 2nd torque boost level selected with 2nd characteristics select switch.
Data setting range
51
Downloaded from
www.Manualslib.com
(Hz) 45.0 to 250
The maximum output frequency will be the
value set in parameter P03 (frequency
range) or parameter P15 (max. output
frequency).
0 to 40 (The output voltage will increase and the boost level
[Constant torque mode]
(Parameter P04: 0)
100
Boost
level
0
Output
frequency (Hz)
manuals search engine
will increase when a larger value is set.).
[Square torque mode]
(Parameter P04: 1)
100
Boost
level
0
Base
Output
frequency
frequency (Hz)
Max. output
frequency (P15)
2nd base frequency
100
0
Output frequency (Hz)
Base
frequency

Advertisement