Panasonic VF0 Series Instruction Manual page 25

Compact inverter 400v class
Hide thumbs Also See for VF0 Series:
Table of Contents

Advertisement

2. Forward/reverse run operation
1) Forward run/reverse run method (Parameter P08 set to "1")
2) Start/stop, rotation direction mode setting method (Parameter P08 set to
3. Combination of "MOP function", "rotation direction setting mode",
and forward/reverse run operation
Forward/reverse run operation
Forward run/reverse run method
Start/stop, rotation direction mode
setting method
Note)
Downloaded from
www.Manualslib.com
Press the
button (forward run) or
to select the rotation direction. Operation will start when the RUN button
is pressed, and will stop when the STOP button is pressed.
∗ The inverter will not start running just by pressing the RUN button.
∗ The MOP function cannot be used if the frequency is set with the
digital method.
"0")
First, press the MODE button twice to enter the rotation direction setting
mode. Press the SET button to display the rotation direction data,
change the rotation direction with the
and then press the SET button to enter the data. (Forward run is set as
the factory setting.)
Operation will start when the RUN button is pressed, and will stop when
the STOP button is pressed.
When the forward/reverse run operation is set to "forward run/
reverse run method", the MOP function cannot be used even if the
frequency is set with the digital method.
manuals search engine
button (reverse run) on the panel
(up) button and
Details of rotation direction
MOP function
× (Cannot be used)
(Can be used)
Monitor function and direction setting
(down) button,
setting mode
Only monitor function
24