3.2.12.4 FUSER UPPER ASSY (PL9.2.30) Removal

1. Remove the EXIT TRAY ASSY. (See Section 3.2.13.1.)
2. Pull out the FUSER ASSY.
3. Remove the MAIN FUSER ASSY. (See Section 3.2.12.2.)
4. Remove the UPPER GUIDE ASSY. (See Section 3.2.12.3.)
5. Free the harness of the TEMP. SENSOR ASSY by unhooking from the
FUSER UPPER ASSY.
NOTE: When the FUSER UPPER ASSY is removed in the following, the
FUSER FRONT COVER and FUSER REAR COVER will no longer be
secured. Be careful not to allow the covers to fall.
6. Remove the 2 screws (gold, w/washer, 8mm) and 2 screws (silver, 6mm)
(total of 4 screws) securing the FUSER UPPER ASSY, and remove the
FUSER UPPER ASSY.
NOTE: Be careful not to damage the surface of the HEAT ROLL with
screwdriver, etc., when removing the TEMP. SENSOR ASSY while
performing the following.
7. Remove the screw (silver, tapping, 14mm) securing the TEMP. SENSOR
ASSY, and remove the TEMP. SENSOR ASSY from the FUSER UPPER
ASSY.
C H E C K
The front screws (gold, w/washer, 8mm) also secure the H/R
P O I N T
HEATER. The rear screws (gold, w/washer, 8mm) also
secure the HEATER WIRE.
Disassembly/Assembly/Adjustment
Disassembly/Assembly Procedures
Figure 3-81. FUSER UPPER ASSY Removal