EPSON Stylus Photo R1900/R2880/R2000/R2000s/SC-P400 Series
When performing the following steps, be careful not to damage the
C A U T I O N
tabs of the Printer Cover Holder Right.
3-3.
Slide the Printer Cover Holder Right in the direction of the arrow while
pushing the part A, and pull out the Printer Cover Holder Right from the
bearing of the Printer Cover.
Bearing
Figure 4-22. Removing the Printer Cover (2)
4.
In the same way, remove the Printer Cover Holder Left and remove the Printer
Cover from the Upper Housing.
A D J U S T M E N T
If the Printer Cover creaks when opening/closing it, make sure to
R E Q U I R E D
lubricate the Printer Cover Holder Left/Right.
• "Chapter 6
Maintenance
Disassembly And Assembly
A
(p.163)"

4.2.8 Upper Housing Support Assy

1.
Remove the Upper Housing / Printer Cover. (p.83)
2.
Remove the two
the Upper Housing Support Assy, and remove the Upper Housing Support Assy.
C.B.P. M3x8
Figure 4-23. Removing the Upper Housing Support Assy
Secure the Grounding Plate with one of the C.B.S. M3 x 8
screws together with the Upper Housing as shown below.
Route the CDR Sensor cable as shown in the figure below.
Removing the Housings
C.B.S. M3 x 8
screws and two
C.B.P. M3 x 8
C.B.S. M3x8
Upper Housing Support Assy
Grounding Plate
Wind the CDR Sensor
cable around the rib one
time.
Figure 4-24. Routing the CDR Sensor Cable
Revision I
screws that secure
C.B.P. M3x8
CDR Sensor cable
85