Error messages

12.22 Err 07-72 (water pressure during WaveClean too low)

Description This fault message is displayed if the pressure switch registered a
Troubleshooting Ensure on-site water supply to soft water connection of unit. The

12.23 Con (configuration required)

Description Configuring is required when the control board is replaced. This
74
Perform the DynaSteam test in the Service menu.
No water runs through the water supply pipe into the cooking
chamber.
Check water supply pipe for calcification.
Ensure that the hose between the steaming unit and supply pipe
is not clogged.
Replace steaming unit.
water pressure that is too low during WaveClean's. The program is
stopped until the water pressure is sufficiently high again.
supply pressure on the water connection must be at least 2 bar. If the
fault occurs sporadically, check the on-site water pressure while
observing nearby water consumers.
message appears if this has not been carried out and saved.
Remedy Configure the unit
Service instructions
(see „5.16 Configuration settings (Con)‟, Page
30).