Converting The Gas Type - Henny Penny FlexFusion FGE 615 Service Instructions Manual

Electric or gas gold combi oven
Hide thumbs Also See for FlexFusion FGE 615:
Table of Contents

Advertisement

9.3 Converting the gas type

DANGER
DANGER
DANGER
DANGER
9. Using the adjusting screw for maximum power, adjust the CO
content to the specified range for high output.
specified range for high output.
Turning counterclockwise: CO
Turning clockwise: CO
If necessary, repeat the adjustment procedure for minimum
power until the CO
minimum capacity is within the specified range.
10.On models with two burners: Repeat the procedure for the second
burner.
11.Check the exhaust gas values (see "Checking the settings").
12.To end the CO
measurement, press the "START STOP" button.
2
13.The indicator light in the "START STOP" button goes out; the
burner is off.
Risk of personal injury and property damage from electric shock
• Before working on the unit, ensure that the unit has been disconnected from
the power supply.
Risk of explosion and fire from escaping gas
• When bleeding air from or degassing the gas system and the unit, ensure
that the air and gas are discharged to the outside in a technically correct
manner and without creating a risk.
Risk of explosion or fire from operating the unit with the wrong
gas type because of missing or incorrect gas type supplemental
label
• When converting to a different gas type, replace the gas type supplemental
label on the unit with the appropriate gas type supplemental label for the
gas type available.
Risk of personal injury and property damage from electric shock
• Inspection and adjustment work that can be carried out only with the hous-
ing open and the unit under power must be performed only by electrically
trained qualified personnel.
Service instructions
content is increased.
2
content is decreased.
2
value at maximum capacity and at
2
Gas technology
level to the
2
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents