Henny Penny FlexFusion FGE 615 Service Instructions Manual page 46

Electric or gas gold combi oven
Hide thumbs Also See for FlexFusion FGE 615:
Table of Contents

Advertisement

Gas technology
DANGER
INFORMATION
Prerequisite Gas connection line connected
46
11.Press the Ready2Cook button.
The left display flashes "LO".
The centre display shows "CO2".
12.Using the left knob, set the burner to high output ("HI").
The left display flashes "HI".
The centre display shows "CO2".
13.Use the right knob to select the first burner "-1-" (on models with
two burners).
The right display flashes "-1-".
14.Press the "START STOP" button.
The indicator light in the "START STOP" button flashes; the
burner starts.
The unit operates at maximum power.
15.Check whether the measured CO
range
If necessary, repeat the adjustment procedure until the CO
value at high and at low output is within the specified range.
If the CO
level at high output is still outside the specified
2
range, the rated heat input must be set manually.
16.On models with two burners: Repeat the procedure for the second
burner.
17.To end the CO
measurement, press the "START STOP" button.
2
18.The indicator light in the "START STOP" button goes out; the
burner is off.
19.Switch off the unit.
Setting without a gas orifice
Risk of personal injury and property damage from electric shock
• Inspection and adjustment work that can be carried out only with the hous-
ing open and the unit under power must be performed only by electrically
trained qualified personnel.
The offset pressure can be measured as an adjustment aid at minimum capac-
ity. This is not a substitute for making the basic gas setting.
Checked for leak tightness outside the unit
Connection pressure checked
Checked for leak tightness inside the unit
Basic gas setting checked
Left side wall removed
1. Remove the gas orifice (see "Converting the gas type").
Service instructions
content is within the specified
2
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents