Gas technology
9.2.2 Adjusting the settings
DANGER
WARNING
INFORMATION
Prerequisite Gas connection line connected
44
a
b
Image: Size 2xx
a Burner 1 (cooking chamber 1)
Risk of personal injury and property damage from electric shock
• Inspection and adjustment work that can be carried out only with the hous-
ing open and the unit under power must be performed only by electrically
trained qualified personnel.
Risk of poisoning from exhaust gases
• Ensure that exhaust gases are discharged properly and that the necessary
amount of combustion air is supplied.
• Ensure that a maximum CO content of < 0.1 vol. % or < 1000 ppm is
achieved in undiluted exhaust gas.
Setting with gas orifice (standard)
The offset pressure can be measured as an adjustment aid at minimum capac-
ity. This is not a substitute for making the basic gas setting.
Checked for leaktightness outside the unit
Connection pressure checked
Checked for leaktightness inside the unit
Basic gas setting checked
Left side wall removed
If the rated heat input is checked and not OK: adjust the rated
heat input.
Service instructions
b Burner 2 (cooking chamber 2)