Error messages
12.11 Err 07-14 ((cooking chamber top sensor emergency program)
Description Emergency operation is activated automatically and displayed.
Location The cooking chamber sensor is in the top right of the cooking
Naming on the circuit
Troubleshooting Unlock and open control panel.
12.12 Err 07-15 ((cooking chamber bottom sensor emergency program)
Description Emergency operation is activated automatically and displayed.
Location The cooking chamber sensor is in the middle right of the cooking
Naming on the circuit
Troubleshooting Unlock and open control panel.
66
Measurement of the cooking chamber temperature is done
exclusively by the bottom cooking chamber sensor.
chamber.
B2
diagram
Check contacting on control board A1, X25.
Remove existing cooking chamber sensor from the control board
A1, X25 and plug in new cooking chamber sensor.
The fault message disappears. Replace cooking chamber
sensor.
The fault message is still displayed. Replace control board.
Measurement of the cooking chamber temperature is done
exclusively by the top cooking chamber sensor.
chamber.
B3
diagram
Check contacting on control board A1, X26.
Remove existing cooking chamber sensor from the control board
A1, X26 and plug in new cooking chamber sensor.
The fault message disappears. Replace cooking chamber
sensor.
The fault message is still displayed. Replace control board.
Service instructions