12.9 Err 07-12 (bottom cooking chamber sensor defective)
Description Emergency operation is activated automatically and displayed.
Location The cooking chamber sensor is in the middle right of the cooking
Naming on the circuit
Troubleshooting Unlock and open control panel.
12.10 Err 07-13 ((cooking chamber sensor emergency program)
Description Emergency operation is activated automatically and displayed. The
Location The cooking chamber sensor is in the top right of the cooking
Naming on the circuit
Troubleshooting Unlock and open control panel.
Measurement of the cooking chamber temperature is done
exclusively by the top cooking chamber sensor.
chamber.
B3
diagram
Check contacting on control board A1, X26.
Remove existing cooking chamber sensor from the control board
A1, X26 and plug in new cooking chamber sensor.
The fault message disappears. Replace cooking chamber
sensor.
The fault message is still displayed. Replace control board.
core temperature sensor takes over the function of the cooking
chamber sensor. Cooking program with core temperature sensor is
no longer available.
chamber.
B2
diagram
Check contacting on control board A1, X25.
Remove existing cooking chamber sensor from the control board
A1, X25 and plug in new cooking chamber sensor.
The fault message disappears. Replace cooking chamber
sensor.
The fault message is still displayed. Replace control board.
Service instructions
Error messages
65