Settings via software

11.19.2Editing parameters in level M2

Prerequisite:
• The machine is in the programming mode, the LED in the Ready button
1. Press and hold the Memory button for 6 seconds.
 The controller beeps 2x; the LED in the button illuminates.
2. Press the +/- Program buttons to select other parameters.
3. Press the Ready button to confirm the parameter.
 The LED in the button illuminates.
4. Press the +/- Function buttons to change values.
5. Press the Reset button to reset a changed value.
6. Press the Ready button to save a change.
 The LED in the button switches off.
7. Press the Memory button.
 The LED in the button switches off.

11.20Resetting parameters to factory settings

Prerequisite:
• The machine is in the programming mode, the LED in the Ready button
1. Press and hold the Memory button for 6 seconds.
 The LED in the button illuminates.
2. Select parameter number U098 by using the +/- Program buttons.
3. Press the Ready button.
4. Enter the function value 1 by using the +/- Function buttons.
5. Press the Selection button.
 The controller beeps 1x. If the controller beeps 3x, the reset was
6. Set parameter U085 for class 532.
Setting parameter U085 (class 532)
After resetting the parameters to the factory setting, parameter U085 must
be set for the button sewing machine.
Prerequisite:
• The machine is in the programming mode, the LED in the Ready button
Service Instructions 512-211-01/532-211-01 - 00.0 - 06/2016
is off.
The Program display shows the parameter numbers; the Function
display shows the values.
is off.
unsuccessful.
is off.
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

532-211-01

Table of Contents