Fig. 13: Light barrier sensor disks
(1) - Thread trimmer sensor disk

4.2 Adjusting the left and right switching flags

The switching flags are used as reference by the control unit for the posi-
tion of the clamps in an X and Y-direction.
Checking the correct setting
 The clamps are centered in both an X and Y-direction.
Faults caused by an incorrect setting
• Damage to the needle
• Incorrect needle position
Cover
• Remove the right-hand side cover ( S. 14).
• Remove the left-hand side cover ( S. 15).
22
Adjusting the light barriers
(2) - Thread wiper and fabric clamp sensor
disk
Service Instructions 512-211-01/532-211-01 - 00.0 - 06/2016