Service settings via software
12.4 Loading software via a USB stick
If a new version of the software becomes available, it can be downloaded
from www.duerkopp-adler.com and loaded onto a USB stick.
Important
The following files must be saved to the USB stick:
• FUYSTS.BT
• LEEYSTS.BT1
• BT1mot
• BT1PAT
12.4.1 Loading the main program
1. Switch on the controller.
2. Insert the USB stick.
3. Press the USB button and wait approx. 3 seconds.
4. Press the Memory button.
5. Press the +/- Function buttons to set value 5 in the Function display.
6. Press the Selection button.
The process for downloading to the controller starts.
Important
If a value is no longer shown in the Function display, the download pro-
cess is complete. Now wait at least 25 seconds, otherwise it could corrupt
the controller!
7. Switch off the controller.
8. Remove the USB stick.
12.4.2 Loading sewing patterns
1. Switch on the controller.
The current software version is briefly displayed.
2. Insert the USB stick.
3. Press the USB button and wait approx. 3 seconds.
Service Instructions 512-211-01/532-211-01 - 00.0 - 06/2016
NOTICE
Property damage may occur!
Damage to the machine as a result of interrupting the copying
process.
Never remove the USB stick during the copying process.
Only remove the USB stick after observing the specified time period.
61