Table 23 :TRIGger[:EDGE] Commands Summary
Command
:TRIGger[:EDGE]:COUPlin
g {AC | DC | LF} (see
page
365)
:TRIGger[:EDGE]:LEVel
<level> [,<source>]
(see
page
366)
:TRIGger[:EDGE]:REJect
{OFF | LF | HF} (see
page
367)
:TRIGger[:EDGE]:SLOPe
<polarity> (see
page
368)
:TRIGger[:EDGE]:SOURce
<source> (see
page
Table 24 :TRIGger:FLEXray Commands Summary
Command
:TRIGger:FLEXray:ERRor:
TYPE <error_type> (see
page
371)
:TRIGger:FLEXray:FRAMe:
CCBase
<cycle_count_base> (see
page
373)
Agilent 6000 Series Oscilloscopes Programmer's Reference
Query
:TRIGger[:EDGE]:COUPlin
g? (see
page
:TRIGger[:EDGE]:LEVel?
[<source>] (see
page
366)
:TRIGger[:EDGE]:REJect?
(see
page
367)
:TRIGger[:EDGE]:SLOPe?
(see
page
368)
:TRIGger[:EDGE]:SOURce?
369)
(see
page
369)
Query
:TRIGger:FLEXray:ERRor:
TYPE? (see
page
:TRIGger:FLEXray:FRAMe:
CCBase? (see
Options and Query Returns
{AC | DC | LF}
365)
For internal triggers, <level> ::=
.75 x full-scale voltage from center
screen in NR3 format.
For external triggers, <level> ::= 2
volts with probe attenuation at 1:1
in NR3 format.
For digital channels (MSO models),
<level> ::= 8 V.
<source> ::= {CHANnel<n> | EXTernal}
for DSO models
<source> ::= {CHANnel<n> |
DIGital0,..,DIGital15 | EXTernal }
for MSO models
<n> ::= 1-2 or 1-4 in NR1 format
{OFF | LF | HF}
<polarity> ::= {POSitive | NEGative
| EITHer | ALTernate}
<source> ::= {CHANnel<n> | EXTernal}
for DSO models
<source> ::= {CHANnel<n> |
DIGital0,..,DIGital15 | EXTernal}
for MSO models
<n> ::= 1-2 or 1-4 in NR1 format
Options and Query Returns
<error_type> ::= {ALL | CODE | TSS |
371)
HCRC | FCRC | END | BOUNdary | IDLE |
SYMbol | SLOT | NULL | SOS | FID |
CCOunt | PLENght}
<cycle_count_base> ::= integer from
page
373)
0-63