Table 20 :TRIGger:CAN Commands Summary (continued)
Command
:TRIGger:CAN:PATTern:ID
<value>, <mask> (see
page
347)
:TRIGger:CAN:PATTern:ID
:MODE <value> (see
page
348)
:TRIGger:CAN:SAMPlepoin
t <value> (see
page
349)
:TRIGger:CAN:SIGNal:BAU
Drate <baudrate> (see
page
350)
:TRIGger:CAN:SOURce
<source> (see
page
:TRIGger:CAN:TRIGger
<condition> (see
page
352)
Agilent 6000 Series Oscilloscopes Programmer's Reference
Query
:TRIGger:CAN:PATTern:ID
? (see
page
347)
:TRIGger:CAN:PATTern:ID
:MODE? (see
page
:TRIGger:CAN:SAMPlepoin
t? (see
page
:TRIGger:CAN:SIGNal:BAU
Drate? (see
page
:TRIGger:CAN:SOURce?
351)
(see
page
351)
:TRIGger:CAN:TRIGger?
(see
page
353)
Options and Query Returns
<value> ::= 32-bit integer in
decimal, <nondecimal>, or <string>
(with Option AMS)
<mask> ::= 32-bit integer in
decimal, <nondecimal>, or <string>
<nondecimal> ::= #Hnn...n where n
::= {0,..,9 | A,..,F} for
hexadecimal
<nondecimal> ::= #Bnn...n where n
::= {0 | 1} for binary
<string> ::= "0xnn...n" where n ::=
{0,..,9 | A,..,F} for hexadecimal
<value> ::= {STANdard | EXTended}
348)
(with Option AMS)
<value> ::= {60 | 62.5 | 68 | 70 | 75
349)
| 80 | 87.5} in NR3 format
<baudrate> ::= {10000 | 20000 |
350)
33300 | 50000 | 62500 | 83300 |
100000 | 125000 | 250000 | 500000 |
800000 | 1000000}
<source> ::= {CHANnel<n> | EXTernal}
for DSO models
<source> ::= {CHANnel<n> |
DIGital0,..,DIGital15 |} for MSO
models
<n> ::= 1-2 or 1-4 in NR1 format
<condition> ::= {SOF} (without
Option AMS)
<condition> ::= {SOF | DATA | ERRor
| IDData | IDEither | IDRemote |
ALLerrors | OVERload | ACKerror}
(with Option AMS)