Parameter Window X: General - ABB i-bus KNX Product Manual

Light controller with sensor lr/s with lf/u, intelligent installation systems
Hide thumbs Also See for i-bus KNX:
Table of Contents

Advertisement

®
ABB i-bus
KNX
3.2.3
Parameter window
X: General
© 2008 ABB STOTZ-KONTAKT GmbH
Commissioning
In this parameter window general settings for the Light Controller
are undertaken.
Select additional function
Options:
none (Switch/Dim actuator)
Light control
Slave mode in lighting control
Staircase light
This parameter defines the additional functions of the LR/S output.
none (Switch/Dim actuator): The output operates purely as
a 1-10 V Switch/Dim actuator.
Light control: The output undertakes lighting control. Depending on
the brightness detected via the Light Sensor, the 1-10 V outputs are
controlled so that the luminance measured by the Light Sensor
(brightness of surfaces underneath the Light Sensor) is kept constant.
The setpoint value should be set via a commissioning routine with
artificial and daylight calibration. Refer for this purpose to the
parameter window
X: Control
the chapter
Constant lighting
The lighting control can be switched on and off via the activate control
communication object. Accordingly, an energy efficient building
automation with optimum brightness during occupancy can be
generated together with the use of a Presence Detector.
The parameter windows
enabled. In these parameter windows the properties of the
lighting control
are parameterised.
Slave mode in lighting control: The output of the light controller is
defined as a slave. This slave output must then be forcibly operated
by a master.
and
X: Control Operating
control.
and
X: Control
X: Control Operating
as well as
are
Constant
33

Advertisement

Table of Contents
loading