16-9 Explanation of various PLC speed mode controls

Speed mode supports SVC control. Under the speed mode of SVC control, it cannot be
performed successfully unless finish motor parameter auto tuning ahead of time.
Control methods and settings are explained as follows:
Speed control:
Register table for speed mode:
Control special M
Special
M
M1025 Driver frequency = set frequency (ON)/driver frequency =0 (OFF)
M1026 Driver operating direction FWD(OFF)/REV(ON)
M1040 Hardware power (Servo On)
M1042 Quick stop
M1044 Pause (Halt)
M1052 Lock frequency (lock, frequency locked at the current operating frequency)
Status special M
Special
M
M1015 Frequency attained (when used together with M1025)
M1056 Servo On Ready
M1058 On Quick Stopping
Control special D
Special
D
D1060 Mode setting (speed mode is 0)
Status special D
Special
D
D1037 Converter output frequency (0.00~600.00)
D1050 Actual operating mode (speed mode is 0)
Speed mode control commands:
FREQ (P)
Target speed
Example of speed mode control:
Before performing speed control, if the SVC control method is used, setting of electromechanical
parameters must first be completed.
1.
Setting D1060 = 0 will shift the converter to the speed mode (default).
2.
Use the FREQ command to control frequency, acceleration time, and deceleration time.
3.
Set M1040 = 1, the driver will now be excited, but the frequency will be 0.
Description of Function
Description of Function
Description of Function
Description of Function
S1
The first acceleration time setting
Chapter 16 PLC Function Applications│CP2000
S2
The first deceleration time setting
16-135
Attributes
RW
RW
RW
RW
RW
RW
Attributes
RO
RO
RO
Attributes
RW
Attributes
RO
RO
S3