Delta CP2000 Series Quick Start Manual

Delta CP2000 Series Quick Start Manual

Fan/pump vector control drive
Hide thumbs Also See for CP2000 Series:

Advertisement

Delta Fan/Pump Vector
Control Drive
CP2000 Series
Quick Start Guide
www.deltaww.com

Advertisement

Table of Contents
loading

Summary of Contents for Delta CP2000 Series

  • Page 1 Delta Fan/Pump Vector Control Drive CP2000 Series Quick Start Guide www.deltaww.com...
  • Page 2 Warning! This is a short guide, and does not give all necessary safety information. Refer to the CP2000 Series User Manual for all safety information to avoid damage to the drive, motor or personal injury. Document Version 1.0 Published August 25, 2017...
  • Page 3: Table Of Contents

    Table of Contents CHAPTER 1 INTRODUCTION ....................3 1-1 Before You Start ....................... 3 CHAPTER 2 CONTROL WIRING ....................4 2-1 Cabling ..........................4 CHAPTER 3 SET UP THE VFD PARAMETERS ............... 5 3-1 About Parameters ......................5 3-2 VFD Digital Keypad ......................5 3-3 Digital Keypad Keys ......................
  • Page 4: Chapter 1 Introduction

    Chapter 1 Introduction Chapter 1 Introduction This Quick Start Guide shows you how to configure the CP2000 Series drive settings to work with your Delta Controls controllers. The guide assumes the drive has already been installed on- site by a qualified technician.
  • Page 5: Chapter 2 Control Wiring

    Chapter 2 Control Wiring Chapter 2 Control Wiring Do not remove the factory jumpers between STO1/STO2/+24V and SCM1/SCM2/DCM. Make sure the AFM1 and AVI1 switches are in the 0-10V position. Make sure the Start Relay shown is not in a closed state when the drive is initially powered up.
  • Page 6: Chapter 3 Set Up The Vfd Parameters

    Chapter 3 Set Up the VFD Parameters Chapter 3 Set Up the VFD Parameters This section describes how to set up the VFD parameters when you turn on the drive for the first time, and how to use the digital keypad on the VFD to access these parameter settings. 3-1 About Parameters The VFD parameters are organized in groups which are numbered from 00 to 13.
  • Page 7: Digital Keypad Keys

    Chapter 3 Set Up the VFD Parameters | CP2000 3-3 Digital Keypad Keys Description of Function When the VFD is in HAND mode, pressing RUN starts the motor. STOP/RESET This key has the highest processing priority in any situation. Pressing STOP stops the VFD whether the VFD is in HAND mode or AUTO mode.
  • Page 8: Display Workflow

    3-4 Display Workflow | CP2000 3-4 Display Workflow 3-5 Setting Up Parameters for the First Time This section describes how to configure the drive correctly after turning it on for the first time. To access the VFD parameters on the keypad display, 1.
  • Page 9: Changes To System Parameters (00) Group

    Chapter 3 Set Up the VFD Parameters | CP2000 To enter a value, use to increase or decrease the number displayed. In some cases when you are presented with a string of numbers, decimal places, dates or times, you may need to use to move the cursor’s position to make a specific change.
  • Page 10: Changes To Basic Parameters (01) Group

    3-5 Setting Up Parameters for the First Time | CP2000 Parameter Display Text Description of Parameter Default Preferred Value Value 00-32 Keypad KPD STOP This determines whether the stop function ENABLE STOP key on the keypad is active when the drive is running in AUTO mode.
  • Page 11: Digital Input / Output Parameters (02) Group

    Chapter 3 Set Up the VFD Parameters | CP2000 Digital Input / Output Parameters (02) group Parameter Display Text Description of Parameter Default Preferred Value Value 02-35 External Fault Reset OP When set to 1, the drive operation after automatically restarts after a reset and activate power failure, assuming the FWD terminal is still closed.
  • Page 12: Special Parameters (07) Group

    3-5 Setting Up Parameters for the First Time | CP2000 Special Parameters (07) group Setting up these parameters is optional but useful to minimize efforts to correct drive faults. Parameter Display Text Description of Parameter Default Preferred Value Value 07-06 Restart Momentary The operation mode when after momentary...
  • Page 13: Communication Parameters (09) Group

    Chapter 3 Set Up the VFD Parameters | CP2000 Parameter Display Text Description of Parameter Default Preferred Value Value 07-12 Speed Restart Method This determines how the search on startup drive starts the motor. This is a useful setting if the drive occasionally starts when the motor is already spinning.
  • Page 14 Preferred Value Value 09-50 BACnet BACnet MS/TP MAC address, range To avoid Dnet Address of 0 127. conflict with Delta NET2 port, do not use 0. 09-51 BACnet BACnet MS/TP Baud rate 9.6, 19.2, 38.4 76.8 Baud Rate BaudRate 38.4, 76.8 kbps...
  • Page 15: Chapter 4 Start Up Test

    The drive should now be starting, and running up to the commanded speed. 11. Adjust the Delta controller's AO value across its range to ensure that the full speed range can be commanded, and that the minimum speed of the drive is being enforced.
  • Page 16: Appendix A Publication History

    Appendix A Publication History Appendix A Publication History Document Date Published Change Description Version August 2017 First release.