09 Communication Parameters

COM1 Communication Address

Settings
 If the AC motor drive is controlled by RS-485 serial communication, the communication address
for this drive must be set via this parameter and each AC motor drive's communication address
must be different.

COM1 Transmission Speed

Settings
 This parameter is for set up the RS485 communication transmission speed.
 Please set 4.8K, 9.6K, 19.2K, 38.4K, 57.6K and 115.2K. If the value is not including in the 6 type
that mentioned, it will be replaced by 9.6K.

COM1 Transmission Fault Treatment

Settings
 This parameter is to set the reaction of MODBUS transmission errors with the host. Detection
time can be set in Pr09-03.

COM1 Time-out Detection

Settings
 It is used to set the communication transmission time-out.
COM1 Communication Protocol
Settings
When us ing communication devi ces,
connects AC dr ive with P C by us ing
Delta IFD6530 or IFD6500.
1~254
4.8~115.2Kbps
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
3: No warning and continue operation
0.0~100.0 sec
1: 7, N, 2 for ASCII
2: 7, E, 1 for ASCII
3: 7, O, 1 for ASCII
4: 7, E, 2 for ASCII
5: 7, O, 2 for ASCII
6: 8, N, 1 for ASCII
 The parameter can be set during the operation.
8
1
Modbus RS- 485
Pin 1~2,7,8: Reserv ed
Pin 3, 6: GND
Pin 4: SG-
Pin 5: SG+
RS-485
12.1-09-1
Factory Setting: 1
Factory Setting: 9.6
Factory Setting: 3
Factory Setting: 0.0
Factory Setting: 1