Field Service Ver. 2.0 Jun. 2010
5.4.23
Ozone filter
1. Remove the toner bottle.
See P.19
2. Remove the imaging unit.
See P.41
3. Remove the drum.
See P.14
4. Remove the drum charge corona assy.
See P.16
[2]
6. To reinstall, reverse the order of removal.
7. Turn ON the power switch.
8. Select [SERVICE MODE] - [CLEAR DATA] - [PM COUNTER] and clear the counter
value of [OZONE].
5.4.24
Multi bypass tray feed roller
1. Remove the multi bypass tray.
See P.40
2. Remove the bypass paper feed clutch.
See P.59
[1]
[1]
[1]
A0XXF2E044DA
[2]
A0XXF2E528DA
5. OTHER MAINTENANCE ITEMS
5. While releasing four tabs [1], remove
the ozone filter [2].
3. Remove four screws [1], and remove
the multi bypass tray upper cover [2].
51