Konica Minolta bizhub 164 Service Manual page 50

Hide thumbs Also See for bizhub 164:
Table of Contents

Advertisement

Field Service Ver. 2.0 Jun. 2010
[1]
[1]
16. To reinstall, reverse the order of removal.
NOTE
• Do not install the toner bottle at this stage.
17. Turn ON the power switch.
18. Perform [SERVICE MODE] - [FUNCTION] - [TCR AUTO ADJUST].
See P.112
NOTE
• To obtain the correct adjustment value, make this adjustment while the toner bot-
tle is removed.
19. Install the toner bottle.
4. PERIODICAL MAINTENANCE PROCEDURE
[3]
[2]
A0XXF2E005DA
[2]
A0XXF2E516DA
14. Tilt the developing unit as shown in
the illustration. While turning the
gear [1] in the direction of the arrow,
dump the developer [2].
NOTE
• Make sure that the magnet roller [3]
is placed on the upper side of the
developing unit when dumping the
developer [2].
Old developer adhering to the gears
and rolls can cause their breakage.
• Turning the gear backward at this
time could damage the sheet for
cleaning the TCR sensor.
• Dump developer until almost no
developer sticks to the magnet
roller.
15. While turning the gear [1] in the
direction of the arrow, pour a packet
of developer [2].
NOTE
• Shake the packet of developer well
before pouring.
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents