14. MALFUNCTION CODE
14.3.13
C5102: Main motor malfunction
Main motor (M1)
Step
1
Check the connector between M1-PRCB
CN6 for proper connection and correct as
necessary.
2
Check M1 for correct drive coupling and
correct as necessary.
3
M1 operation check.
4
Change PRCB.
5
Change DCPU.
14.3.14
C6101: Scanner home detection failure
Scanner motor (M4)
CIS module (CIS)
Step
1
Turn OFF and ON the power switch.
2
Check the connector between M4-PRCB
P101 for proper connection and correct as
necessary.
3
Check M4 for correct drive coupling and
correct as necessary.
4
Check the connector between CIS-PRCB
P102 for proper connection and correct as
necessary.
5
M4 operation check
6
Change M4.
7
Change CIS
8
Change MFPB.
134
Relevant electrical components
Operations
Relevant electrical components
Operations
Field Service Ver. 2.0 Jun. 2010
Printer control board (PRCB)
DC power supply (DCPU)
WIRING DIAGRAM
Control signal
-
-
PRCB CN6-7 (LOCK)
-
-
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
–
–
–
–
PRCB P101-1 to 4
–
–
–
Location
(Electrical compo-
nents)
-
-
D-9
-
-
Location
(Electrical compo-
nents)
–
–
–
–
F-11
–
–
–