Canon Oce PlotWave 300 Administration Manual page 270

Table of Contents

Advertisement

Applications, protocols and ports used in the Océ ColorWave 650 R3.x system
* Océ back-channel is an Océ proprietary protocol used to retrieve information from the printer
(status, media loaded...) and to display it in the application or driver.
(1)
FTP passive mode only (FTP active mode not supported).
Scanning applications with Océ ColorWave 650 R3.x: INBOUND and OUTBOUND ports and
protocols used by the system
Application /Functionality
Scan to File: SMB
Scan to File: FTP
Scan data retrieval from Smart
Inbox (Scans)
Notes:
(1)
FTP passive mode only (FTP active mode not supported).
Control management with Océ ColorWave 650 R3.x0: INBOUND and OUTBOUND ports and
protocols used by the system
Application /Functionality
PING IPv4
PING IPv6
nslookup
SNMP based applications
Name resolution
Océ Express WebTools
Océ Account Center
Accounting information re-
trieval
Océ Meter Manager
Océ back-channel
270
Chapter 5 - Security on Océ ColorWave 550/600/650 (and Poster Printer)
INBOUND ports on the con‐
troller: protocol
TCP 80: HTTP
TCP 443: HTTPS
INBOUND ports on the con‐
troller: protocol
ICMPv4
ICMPv6
UDP local port : any
UDP remote port : 53
UDP 161: SNMP
Outgoing connection:
Local port (on controller):
UDP(/TCP) <dynamic value>
TCP 80: HTTP
TCP 443: HTTPS
TCP 80: HTTP
TCP 80: HTTP
UDP 161: SNMP
TCP 65200 for OCI back-chan-
nel
OUTBOUND ports from the
controller: protocol
TCP 139, 445
UDP 137, 138, 445
(1)
FTP command
:
- Local: TCP any
- Remote: TCP 21
(1)
FTP Data
:
- Local : TCP any
- Remote: TCP any
OUTBOUND ports from the
controller: protocol
Remote port (on DNS server):
UDP(/TCP) 53
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents