Application /Functionality
nslookup
SNMP based applications
Name resolution
Océ Express WebTools
Océ Account Center
Accounting information re-
trieval
Océ Meter Manager
Océ back-channel
Océ Remote Service
NetBios over TCP/IP
WSD
WAVE
OBIS
IPsec
Notes:
(1)
When there is a proxy.
Additional built-in Windows firewall rules
Inbound rules:
• Core Networking - Dynamic Host Configuration Protocol (DHCP-In)
• Core Networking - Dynamic Host Configuration Protocol for IPv6(DHCPV6-In)
Outbound rules:
• Core Networking - DNS (UDP-Out)
• Core Networking - Dynamic Host Configuration Protocol (DHCP-Out)
• Core Networking - Dynamic Host Configuration Protocol for IPv6 (DHCPV6-Out)
• Core Networking - IPv6 (IPv6-Out)
INBOUND ports on the con‐
troller: protocol
UDP local port : any
UDP remote port : 53
UDP 161: SNMP
Outgoing connection:
Local port (on controller):
UDP(/TCP) <dynamic value>
TCP 80: HTTP
TCP 443: HTTPS
TCP 80: HTTP
TCP 80: HTTP
UDP 161: SNMP
TCP 65200 for OCI back-chan-
nel
UDP 137
TCP 80: HTTP
UDP 3702 for WSD discovery
TCP 5357 for WSD eventing
TCP 80: HTTP
TCP 80: HTTP for back-channel
(Océ Publisher Select)
UDP 500
UDP 4500
Chapter 3 - Security on Océ PlotWave 500 and PlotWave 340/360
Applications, protocols and ports
OUTBOUND ports from the
controller: protocol
Remote port (on DNS server):
UDP(/TCP) 53
TCP 443: HTTPS
(1)
TCP web proxy port
TCP 139, 445
UDP 138
101