Wiring Cnp1, Cnp2, And Cnp3 - Mitsubishi Electric MR-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MR-J5 Series:
Table of Contents

Advertisement

Wiring CNP1, CNP2, and CNP3

• For the wire sizes used for wiring, refer to the following.
Page 166 Selection example of wires
• When wiring, remove the power connectors from the servo amplifier.
• Insert only one wire or ferrule into each wire insertion hole on the power connectors.
To wire to CNP1, CNP2 and CNP3, use the servo amplifier power connectors that came with the amplifier.
Connector
■MR-J5-10_ to MR-J5-100_
CNP1
CNP2
CNP3
Connector Receptacle assembly
CNP1
06JFAT-SAXGDK-K7.5 (LA)
CNP2
05JFAT-SAXGDK-K5.0 (LA)
CNP3
03JFAT-SAXGDK-K7.5 (LA)
■MR-J5-200_/MR-J5-350_
CNP1
CNP2
CNP3
Connector Receptacle assembly
CNP1
06JFAT-SAXGFK-XL (LA)
CNP2
05JFAT-SAXGDK-H5.0 (LA)
CNP3
03JFAT-SAXGFK-XL (LA)
3 SIGNALS AND WIRING
44
3.3 Explanation of power supply system
Applicable wire
Size
Insulator OD
AWG 18 to 14
3.9 mm or shorter
Applicable wire
Size
Insulator OD
AWG 16 to 10
4.7 mm or shorter
AWG 18 to 14
3.9 mm or shorter
AWG 16 to 10
4.7 mm or shorter
Stripped length
Open tool
[mm]
9
J-FAT-OT-K
Stripped length
Open tool
[mm]
11.5
J-FAT-OT-EXL
9
11.5
Manufac
turer
JST
Manufac
turer
JST

Advertisement

Table of Contents
loading

Table of Contents