Scale Name; Code For Regulations - Siemens SIWAREX WT241 Manual

Electronic
Table of Contents

Advertisement

Variable
Note
Software version for
HMI SecureDisplay ver-
HMI SecureDisplay
sion
with verification ca-
pability
(Page 107)(available
soon)
Minimum display
HMI SecureDisplay with
size in % of the HMI
verification capability
SecureDisplay with
verification capability
(Page 107)
(available soon)
Reserve
Parameter for calculation of calibration points
1)
11.4.1

Scale name

You can select any name, but it may not exceed 12 characters. You can enter any
designation.
Note
If the jumper is closed to protect data with verification capability, the parameter can no longer
be changed.
11.4.2

Code for regulations

Trade scales requiring verification are subject to certain restrictions (available soon).
0 – no verification
1 – verification in accordance with OIML R50
2 – verification in accordance with NTEP Book 44
(approvals available soon).
Note
If the jumper is closed to protect data with verification capability, the parameter can no longer
be changed.
SIWAREX WT241
Manual, 05/2015, A5E36046748Aa
Type
L
Rw
CHAR[12]
12
USHORT
USHORT
Communication
11.4 DR 3 Belt scale parameters
Default
Min.
Max.
V1.05.0
2
Register
1052
1058
101