Rs485 Protocol; Rs485 Baud Rate; Rs485 Character Parity; Decimal Place For Siebert Indicator - Siemens SIWAREX WP321 Operating Instructions Manual

Electronic weighing system
Hide thumbs Also See for SIWAREX WP321:
Table of Contents

Advertisement

Variable
Note
Bit 2
Reserve (13
Reserve
bits)
Reserve
Reserve
Decimal
Decimal place for Siebert display
place for Sie‐
bert indicator
(Page 81)
Reserve
Reserve
Reserve
Reserve
8.11.1

RS485 protocol

This parameter defines the protocol for communication via the RS485 interface.
8.11.2

RS485 baud rate

This parameter defines the baud rate for the RS485 interface.
8.11.3

RS485 character parity

This parameter defines the character parity for the RS485 interface.
8.11.4

Decimal place for Siebert indicator

A fixed decimal place must be specified if a Siebert indicator is used. The following values are
permitted: 0 ... 4
8.12

DR 14 SIMATIC interface parameters

The parameters which define the response of the SIMATIC interface are specified in data
record DR 14. It is possible to define the process values to be output on the basis of the I/O area.
Procedure
● Check the parameters and modify them as required
● Transfer the data record to the scale
SIWAREX WP321
Operating Instructions, 08/2019, A5E33715669A-AD
8.12 DR 14 SIMATIC interface parameters
Type
L
Rw
BIT
0
rw
BIT
0
rw
UINT
2
rw
INT
2
rw
UINT
2
rw
REAL
4
rw
Scale parameters and functions
Default
Min.
0
0
0
0
20
1
0
-
0
-
0
-
Max.
1
1
255
-
-
-
81

Advertisement

Table of Contents
loading

Table of Contents