 "3: ITF": Minimum number of digits to be read for ITF
 "4: STF": Minimum number of digits to be read for STF
 "5: CODABAR": Minimum number of digits to be read for Codabar
Set minimum number of digits for the code to be scanned.
Press [ ] to decrease the setting value and [ ] to increase the setting value.
ITF entry range:
STF entry range:
Codabar entry range:
Setting a small number of digits increases the frequency of missing digits when scanning or incorrectly
scanning depending on how barcodes are scanned or the quality of barcodes. On the other hand, setting
a large number will decrease the possibility of such errors.
 "6: SCAN MODE"
It is possible to perform scanning in normal mode or point scan mode.
0: Normal mode
Barcodes that lie within the size of the field of view can be scanned.
Refer to "Chapter 8 Specifications" for details of the field of view size.
1: Point scan mode
Only scan barcodes that lie on the guide marker line.
Scanning is not possible if there is no barcode on the guide marker.
Furthermore, in cases where the guide marker cannot be detected due to ambient light and so on,
scanning is performed at roughly the center of the field of view.
 "7: MARKER": Guide Marker
It is possible to select whether to illuminate the guide marker when the trigger switch is pressed.
0: ON (Illuminates the guide marker.)
1: OFF (Does not illuminate the guide marker.)
 "8: SENSOR OFF TIME": Scanning area power OFF time
It is possible to set the time from when the trigger switch is turned OFF until the scanning area (sensor)
power is turned OFF.
OFF time setting range: 0 – 30 seconds
2 - 20
(Default: 4)
1 - 20
(Default: 3)
3 - 20
(Default: 4)
(Default: 0 seconds)