Measurement Data That Can Be Logged For Edge Pitch; Errors - Omron FQ2-S/CH Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Measurement Data That Can Be Logged for Edge Pitch

The following values can be logged as measurement data.
Measured item
Judgement
Edge pitch
Average pitch
Max. pitch
Min. pitch
Average width
Max. width
Min. width
*
When logging data is output, the data is output in the order of the above table.
7-6 Logging Measurement Data and Image Data: p. 392

Errors

Edge Not Found
The measured edge pitch will be 0. Perform the following.
• If a color was specified, make sure the color of the measurement object has not changed from the specified color.
• Set the color again if necessary.
• If there is an edge and it cannot be detected, make sure the [Edge level] parameter on the [Details] Tab Page is cor-
rect.
Edge level: p. 276
292
Inspecting with the Edge Pitch Inspection Item
Range of value
−2: No judgement (not measured)
0: Judgement is OK
−1: Judgement is NG
−13: Teaching not performed error
−14: Figure not registered error
−15: Out of range error
0 to 999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
Description
This is the judgement result from the measurements.
This is the number of objects that were detected.
This is the average pitch that was detected.
This is the maximum pitch that was detected.
This is the minimum pitch that was detected.
This is the average width that was detected between edges.
This is the maximum width that was detected between
edges.
This is the minimum width that was detected between
edges.
FQ2-S/CH User's Manual