Select the Results to Output

You can use multiple conditions to determine which results to output from all the objects detected with a
correlation at the candidate level or higher.
Only the results that meet all the specified conditions are output.
[Inspect] − [Inspection] − [Search] − [Modify] − [Details] Tab Page − [Meas. Parameter]
1
Press [Extraction condition] and adjust the
candidate level so that only objects higher
than a certain correlation are detected.
2
If [Multi-point output] is set to [Yes], you can
specify the output conditions for more than
one result.
(Extraction X/Y and Detection count)
Extraction condition
Range: 0 to 100
Candidate level
Defaults: Lower: 70
Range :-99999.9999 to 99999.9999
Extraction X
Defaults: Lower: -99999.9999
Range :-99999.9999 to 99999.9999
Extraction Y
Defaults: Lower: -99999.9999
Detection count
Range: 1 to 32
Default: 32
Note
The processing time changes if you change the candidate level.
FQ2-S/CH User's Manual
Range
Upper: 100
Upper: 99999.9999
Upper: 99999.9999
Description
Set the threshold to find Candidate. Output the correlat-
ing value that is higher than [Candidate level] value.
Decrease the value when Model search is unstable.
Results are output only for objects with a measured X
coordinate that is within this range.
Results are output only for objects with a measured Y
coordinate that is within this range.
Sets the maximum number of detection results to output.
Inspecting with the Search Inspection Item