Unstable Edge Pitch Results (Sensors with Color Cameras Only)
If the measurement result is not stable, adjust the [Edge level], [Noise level], and [Set color.] parameters.
p. 276
Increasing Edge Pitch Processing Speed
Make the measurement region smaller to reduce the processing time.
Changing the measurement region: p. 227
Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be output to external devices or used in calculations as measurement data.
Expression
Data name
text string
JG
Judgement
N
Edge pitch
P
Average pitch
PH
Max. pitch
PL
Min. pitch
W
Average width
WH
Max. width
WL
Min. width
4-18 Calculations and Judgments Using Inspection Item Data: p. 323
FQ2-S/CH User's Manual
Description
−2: No judgement (not measured)
0: Judgement is OK
−1: Judgement is NG
−13: Teaching not performed error
−14: Figure not registered error
−15: Out of range error
0 to 999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
0 to 99999.9999
Data range
This is the judgement result.
This is the number of objects.
This is the average pitch.
This is the maximum pitch.
This is the minimum pitch.
This is the average width between edges.
This is the maximum width between edges.
This is the minimum width between edges.
Inspecting with the Edge Pitch Inspection Item
291