Measurement Data That Can Be Logged (Color Data)

The following values can be logged as measurement data.
Measured item
Judgement
R average
G average
B average
Color diff./dens. AV. Color
(for Sensors with Color
Cameras)
Color diff./dens. AV. Color
(for Sensors with Mono-
chrome Cameras)
Clr. deviat.
(for Sensors with Color
Cameras)
Clr. deviat.
(for Sensors with Mono-
chrome Cameras)
*
When logging data is output, the data is output in the order of the above table.
7-6 Logging Measurement Data and Image Data: p. 392

Increasing Processing Speed for Color Data

Make the measurement region smaller to reduce the processing time.
Changing the measurement region: p. 227
FQ2-S/CH User's Manual
Range of value
0: Judgement is OK,
−1: Judgement is NG
−10: Image error
−13: Teaching not performed error
−14: Figure not registered error
−15: Out of range error
−20: Other error
0 to 255
0 to 255
0 to 255
0 to 442
0 to 255
0 to 221
0 to 127
Description
This is the measurement judgment results.
This is the average value for the R (red) compo-
nent.
This is the average value for the G (green) compo-
nent.
This is the average value for the B (blue) compo-
nent.
This is the difference between the color that was
registered as the reference and the measured color.
The average color within the measurement area is
used in both cases.
This is the difference between the average density
in the region and the currently measured density.
This is the deviation within the measurement
region.
This is the deviation in the average density in the
measurement region.
Inspecting with Color Data Inspection Item