Increasing Processing Speed; Judgment Is Ng (Insufficient Memory) - Omron FQ2-S/CH Series User Manual

Smart camera
Hide thumbs Also See for FQ2-S/CH Series:
Table of Contents

Advertisement

Increasing Processing Speed

The following two methods can be used to reduce processing time.
• Reduce the range in which a shape search III is performed for the model.
Changing the Measurement Region: p. 227
• Reduce the Angle range setting.
Adjust the [Angle range] parameter to reduce the range in which a shape search II for the model is performed.
Select the Results to Output: p. 237
• Raise [Candidate level].
Raise [Candidate level], then processing time will be shortened.
Select the Results to Output p. 221
• Set the Model region as small as possible.
Raise [Candidate level], then processing time will be shortened.
Step 2 Teaching: p.142

Judgment is NG (Insufficient memory)

The measurement region is possible to use large memory.
Set the measurement region as smaller as possible.
• Set the measurement region to be small.
Changing the Measurement Region: p. 227
・Set the model region to be small.
The model size is possible to use large memory.
Set the model region as smaller as possible.
FQ2-S/CH User's Manual