Reflect in Total Judgment

You can specify whether to reflect the judgment results of an inspection item in the overall judgment.
The Default is to reflect them.
[Inspect] − [Inspection] − [Add item.] − [Shape Search II] − [Details] Tab Page −
[Output parameter]

Unstable Shape Search II Results

Inclined Measurement Objects
Adjust the [Angle range] parameter to increase the range in which a search is made for the model.
The Shape Search II inspection item judges whether an image is OK or NG according to the correlation with a
previously registered image pattern.
For this reason, if the object is at an angle, the correlation is reduced and the image may be judged as NG. To
achieve an OK judgment for the same image pattern even when the object is at an angle, the rotation range
must be widened.
[Inspect] − [Inspection] − [Shape Search II] − [Modify] − [Details] Tab Page − [Model parameter]
1
Set [Rotation] to [Yes].
2
Press [Angle range] and set the following range.
Parameter
Range: −180 to 180
Default: Lower: −180
Angle range
FQ2-S/CH User's Manual
Setting
A shape search II is performed within the set angle range.
The larger the angle range, the longer the processing time.
Important
Upper: 180
If you change the angle range, perform teaching again.