Error
code
75
76
77
80
8 1
82
83
Division
Speed revision
processing
Start
processing
Speed revision
processing
Contents and remedy
Abnormal data type code. Data type other than 1
2,
8 0
Data number exceeds
399.
At time of status readout, data type other than 1
2,
4.
Speed preset value exeeds
9999.
X-axis designation data number exceeds
399.
More than 1 0 change pattern
preset data.
~-
Different direction designation within change pattern
setting data.
Y-axis
preset
data number exceeds
399.
Interpolation
preset
data number exceeds
399.
Non-matching pattern at time of interpolation start.
During interpolation run, X-axis and Y-axis pattern
designation must be a matching 00 or 01.
~~~
~-
Exceeds range of stroke limit.
Positioning data ad-
dress must be lower than upper stroke limit and
higher than lower stroke limit set by parameters.
At time of X-axis start, sequencer ready signal (YlD)
is
OFF.
At time of Y-axis start, sequencer ready signal (YlD)
is
OFF
At time of interpolation start, sequencer ready signal
(YlD) is
OFF.
Speed revision not possible during interpolation start.
Speed revision cannot be performed during interpolation
run.