Mitsubishi MELSEC-K Instruction Manual page 100

Hide thumbs Also See for MELSEC-K:
Table of Contents

Advertisement

Error
code
0
1
2
3
4
5
6
7
8
9
1 0
11
13-2
Error code chart
Division
KCPU write-in
processing
Contents and remedy
Normal
______
No designation for parameter, zero point return data,
positioning data, or status. With a plurality ON,
assign a priority to the above data and perform write-
in.
During parameter write-in, sequencer
ready
signal
(Y't
D)
is ON.
Y1D is
OFF.
Parameter write-in can be performed only when
Parameter continuous write-in is faulty. When writ-
ing in speed restriction or stroke limit, Y-axis
designation or data other than parameters was
designated.
Zero point data cannot be written in during execution
of zero point return.
Continuous write-in of zero point return data is
faulty. When writing in zero point address, zero
point return speed, or zero point creep speed, Y-axis
designation or data other than zero point return data
was designated.
Continuous write-in of positioning data is faulty.
When writing in positioning address and speed,
Y-axis designation or data other than positioning
data was designated.
Continuous write-in of parameters is faulty.
Zero point data cannot be written in during execu-
tion of zero point return.
Continuous write-in of zero point return data is
faulty.
Continuous write-in of positioning data is faulty.
No axis designation.
Neither X-axis nor Y-axis
designated.
If X-axis and Y-axis are both designated,
data will be processed as Y-axis data.
-96-