Mitsubishi FX3U-232-BD User Manual page 427

Fx3u series
Hide thumbs Also See for FX3U-232-BD:
Table of Contents

Advertisement

FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
FREQROL F700 Series
Pr
Function
No.
Terminal 2 frequency setting
125
gain frequency
Terminal 4 frequency setting
126
gain frequency
PID control automatic switchover
127
frequency
128
PID action selection
129
PID proportional band
130
PID integral time
PID operation
131
PID maximum
132
PID minimum
133
PID action set point
134
PID differential time
Commercial power−supply
135
switchover sequence output
terminal selection
136
MC switchover interlock time
Commercial
137
Waiting time at a start
power
Commercial
supply-
138
operation switchover selection at
inverter
an alarm
switch-over
Automatic switchover frequency
between inverter and
139
commercial power-supply
operation
Backlash acceleration stopping
140
frequency
Backlash acceleration stopping
141
time
Backlash
measures
Backlash deceleration stopping
142
frequency
Backlash deceleration stopping
143
time
144
Speed setting switchover
PU
145
PU display language selection
148
Stall prevention level at 0V input.
Stall prevention level at 10V
149
input.
150
Output current detection level
Current
detection
Output current detection signal
151
delay time
152
Zero current detection level
153
Zero current detection time
Voltage
154
during stall prevention operation
RT
signal
155
selection
Stall
156
selection
157
OL signal output timer
158
AM terminal function selection
Automatic switchover ON range
159
between
supply and inverter operation
160
User group read selection
Name
Pr No.
125
126
127
128
129
130
131
132
133
134
135
136
137
power-supply
138
139
140
141
142
143
144
145
148
149
150
151
152
153
reduction
selection
154
reflection
time
155
prevention
operation
156
157
158
commercial
power−
159
160
FREQROL A700 Series
Name
Terminal 2 frequency setting
gain frequency
Terminal 4 frequency setting
gain frequency
PID control automatic switchover
frequency
PID action selection
PID proportional band
PID integral time
PID upper limit
PID lower limit
PID action set point
PID differential time
Electronic
bypass
sequence
selection
MC switchover interlock time
Start waiting time
Bypass selection at an alarm
Automatic switchover frequency
from inverter to bypass operation
Backlash acceleration stopping
frequency
Backlash acceleration stopping
time
Backlash deceleration stopping
frequency
Backlash deceleration stopping
time
Speed setting switchover
PU display language selection
-
Stall prevention level at 0V input
Stall prevention level at 10V
input
Output current detection level
Output current detection signal
delay time
Zero current detection level
Zero current detection time
Voltage
reduction
selection
during stall prevention operation
RT signal function validity
condition selection
Stall
prevention
operation
selection
OL signal output timer
AM terminal function selection
Automatic switchover frequency
range from bypass to inverter
operation
User group read selection
12 Related Data
12.5 FREQROL Inverter Parameter List
FREQROL E700 Series
Pr
Name
No.
Terminal 2 frequency setting
125
gain frequency
Terminal 4 frequency setting
126
gain frequency
PID control automatic switchover
127
frequency
128
PID action selection
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
145
PU display language selection
146
Built-in potentiometer switching
150
Output current detection level
Output current detection signal
151
delay time
152
Zero current detection level
153
Zero current detection time
Stall
prevention
operation
156
selection
157
OL signal output timer
160
User group read selection
E-137
A
B
C
D
E
F
G
H
I
Apx.