FX Series PLC User's Manual - Data Communication Edition
Inverter Communication
2. Changing the speed using a sequence program
M8000
RUN
monitor
3. Controlling operations of an inverter
X000
Operation stop
command input
X001
Forward
rotation
command
input
X002
Reverse
rotation
command
input
M15
Operation
stop
M8000
RUN
monitor
M17
Command for
switching to
speed 1
M18
Command for
switching to
speed 2
FNC271
K0
IVDR
X000
Operation stop
command input
X001
X002
Forward
Reverse
rotation
rotation
command
command
input
input
X002
X001
Reverse
Forward
rotation
rotation
command
command
input
input
FNC271
K0
IVDR
10 Practical Program Examples (for FX3U and FX3UC PLCs)
FNC 12
K6000
D10
MOV
P
Operation
speed
FNC 12
K4000
D10
MOV
P
Operation
speed
FNC 12
K2000
D10
MOV
P
Operation
speed
H0ED
D10
K1
Operation
speed
SET
M15
Operation
stop
RST
M15
Operation
stop
M21
Forward rotation
command
M22
Reverse rotation
command
H0FA
K2M20
K1
10.1 Practical Example 1
"60 Hz" is written as
the initial value at
startup
The operation speed
"40 Hz" is written
The operation speed
"20 Hz" is written
The preset frequency is
written to the inverter
H0FA is set to "00H"
Operation stop is reset
by input X001 or X002
b1 of H0FA is set to ON
b2 of H0FA is set to ON
Operation command is
written
M27 to M20→H0FA