Limit Switches

Limit Switch es
2-1 Limit Switc hes
2-1
Limit Switches
How to Access the Limit
Switches
1
Position the Super Straddle on a firm, level
surface and apply the brakes to swivel casters
at the end frames.
2
Fully lower the straddle frame and remove the
retaining pin from the straddle frame.
3
At the base of the end frame, tag and
disconnect each cable from the limit switch
pigtails.
Note: While performing step 4, use caution when
removing the limit switch cover from the straddle
frame. The retaining pin plate may separate from
the assembly.
4
Using the illustration below as a guide, remove
the fasteners securing the limit switch cover to
the straddle frame assembly. Set the
fasteners to the side and carefully remove the
limit switch cover from the straddle frame
assembly. Set the retaining pin plate to the
side.
5
Remove the fasteners securing the limit
switch(es), to the switch cover and switch
bracket. Set the fasteners, the switch cover
and bracket to the side.
6
Replace the limit switch(es) as necessary.
Use the Electrical Schematic to wire the new
switch(es).
22
1 Screw
2 nylock nut
3 retaining pin
4 retaining pin plate
5 limit switch
6 limit switch bracket
7 limit switch cover
8 screw
9 nylock nut
Super Straddle