DB19
DBX26.5
Unload (job list selection from PLC, status)
Edge evaluation: No
Signal state 1 or
Unload active
edge change 0 → 1
Signal state 0 or
Unload inactive
edge change 1 → 0
Corresponding to ...
Valid for HMI Advanced
DB19
DBX26.6
Load (job list selection from PLC, status)
Edge evaluation: No
Signal state 1 or
Loading active
edge change 0 → 1
Signal state 0 or
Loading inactive
edge change 1 → 0
Corresponding to ...
Valid for HMI Advanced
DB19
DBX26.7
Selection (job list selection from PLC, status)
Edge evaluation: No
Signal state 1 or
Selection active
edge change 0 → 1
Signal state 0 or
Selection inactive
edge change 1 → 0
Corresponding to ...
Valid for HMI Advanced
DB19
DBB27.
Error program handling
Edge evaluation: no
19.1.6
Signals to channel (DB21, ...)
DB21, ...
DBX6.2
Delete distancetogo (channelspecific)
Edge evaluation: no
Signal state 1 or
Delete distancetogo (channelspecific):
edge change 0 → 1
IS "Delete distancetogo (channelspecific)" for path axes is only active in AUTOMATIC mode.
The rising edge of the interface signal is only effective for the axes involved in the geometry
grouping. These are also stopped with a ramp stop and their distancetogo deleted (setpoint -
actual value difference). Any remaining following error is not removed. The next program block is
then started.
IS "Delete distancetogo (channelspecific)" is therefore ignored by positioning axes.
Note:
IS "Delete distancetogo" does not influence the running dwell time in a program block with dwell
time.
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
Signal(s) updated: Cyclic
Signal(s) updated: Cyclic
Signal(s) updated: Cyclic
Signal(s) updated: Cyclic
Signal(s) updated: cyclic
Z1: NC/PLC interface signals
19.1 Various interface signals and functions (A2)
1623