Monitoring and Controlling
• Projector input port name: RS-232C
<At the projector>
<At the projector>
Signal Name
Function
GND
Signal wire ground
Transmit data
TD
Receive data
RD
Communications protocol
• Default baud rate setting: 9600 bps
• Data length: 8 bit
• Parity: None
• Stop-bit: 1 bit
• Flow control: None
<At the computer>
(PC serial cable)
<At the computer>

About PJLink

PJLink was established by the JBMIA (Japan Business Machine and
Information System Industries Association) as a standard protocol for
controlling network-compatible projector's as part of their efforts to
standardize projector control protocols.
The projector complies with the PJLink Class2 standard established by the
JBMIA.
The port number used by the PJLink search function is 4352 (UDP).
You need to make network settings before you can use PJLink. See the
following for more information on network settings.
"Network Menu"
p.127
s
It complies with all commands except for the following commands defined
by PJLink Class2, and agreement was confirmed by the PJLink standard
adaptability verification.
URL:
http://pjlink.jbmia.or.jp/english/
• Non-compatible commands
Function
Mute settings
Image muting set
Audio muting set
• Input ports and corresponding input source number
Input Port Name
HDMI1
HDMI2
HDBaseT (EB-5535U/EB-5530U/
EB-5520W only)
Computer
197
PJLink Command
AVMT 11
AVMT 21
Input Source Number
32
33
56
11