Unit; Table 6-7 Unit For Pressure Measured Value Display - Siemens SITRANS P300 Operating Instructions Manual

With hart communication
Table of Contents

Advertisement

6.5.15

Unit

Introduction
In mode 14, set the physical unit in which the device's measured value display should be
represented.
Requirement
You are familiar with the correct operation of the transmitter and the associated safety
information.
You have already selected the desired measured value display in mode 13.
Procedure
To adjust the physical unit, proceed as follows:
1. Set mode 14.
2. Select a unit.
3. Save with the <Mode> key.
Units
Table 6-7
Unit
mbar
bar
mm water gauge (4°C/39°F)
Inch water gauge (4°C/39°F)
ATM
Torr
g/cm
Kg/cm
MPa
KPa²
Pa
Psi
mm mercury column
mm water gauge (20°C/68°F)
Foot water gauge (20°C/68°F)
Inch mercury column
Inch water gauge (20 °C/68 °F)
SITRANS P300 with HART communication
Operating Instructions, 06/2005, A5E00359579-02
Unit for pressure measured value display
2
2
Display
mbar
bar
m4H2O
i4H2O
ATM
TORR
Gcm2
KGcm2
MPa
KPa
Pa
PSi
mmHG
mmH2O
FTH2O
in_HG
InH2O
Operation
6.5 Local operation
6-33

Hide quick links:

Advertisement

Table of Contents
loading