Specifications
9.1
SITRANS P300 gauge pressure / absolute pressure
Specifications
Gauge pressure input
Measured variable
Measuring span
•
•
•
•
•
•
•
Lower measuring limit
•
•
Upper measuring limit
•
•
Absolute pressure input
Measured variable
Measuring span
•
•
•
SITRANS P300 with HART communication
Operating Instructions, 06/2005, A5E00359579-02
8 ... 250 mbar g (0.12 ... 3.6 psi g)
0.01 ... 1 bar g (0.15 ... 14.5 psi g)
0.04 ... 4 bar g (0.58 ... 58 psi g)
0.16 ... 16 bar g (2.3 ... 232 psi g)
0.6 ... 63 bar g (9.1 ... 914 psi g)
1.6 ... 160 bar g (23.2 ... 2321 psi g)
4.0 ... 400 bar g (58 ... 5802 psi g)
Measuring cell with silicone oil
Measuring cell with inert liquid
For process temperature ϑ
-20 °C < ϑ ≤ 60 °C (-4 °F < ϑ ≤ 140 °F)
For process temperature ϑ
60 °C < ϑ ≤ 100 °C (140 °F < ϑ ≤ 212 °F)
Measuring cell with silicone oil
Measuring cell with inert liquid
8 ... 250 mbar a (0.12 ... 3.6 psi a)
0.043 ... 1.30 bar a (0.62 ... 19 psi a)
0.16 ... 5 bar a (2.3 ... 73 psi a)
Gauge pressure
Maximum permissible operating pressure
2 bar g (29 psi g)
4 bar g (58 psi g)
7 bar g (102 psi g)
21 bar g (305 psi g)
67 bar g (972 psi g)
167 bar g (2422 psi g)
400 bar g (5802 psi g)
30 mbar a (0.44 psi a)
30 mbar a (0.44 psi a)
30 mbar a + 20 mbar a • (ϑ - 60 °C)/°C
(0.44 psi a + 0.29 psi a • (ϑ - 108 °F)/°F)
100% of maximum measuring span
100% of maximum measuring span
Max. 160 bar g (2320 psi g) for oxygen
measurement
Absolute pressure
Maximum permissible operating pressure
1.5 bar a (22 psi a)
2.6 bar a (38 psi a)
10 bar a (145 psi a)
9
9-1