5.9.2 G056/G058 NIB FIRMWARE MODIFICATION HISTORY
G056/G058 NIB FIRMWARE MODIFICATION HISTORY
DESCRIPTION OF MODIFICATION
Firmware modified to correct the following.
1. After a job is canceled from a Unix
terminal, the NIB cannot print any print
jobs sent from the network.
2. Bi-directional communication over TCP
port 9100 is not possible.
3. The NIB stopped LPR printing after user
"root" deleted all the spooled jobs.
4. The NIB stopped LPR printing following
an input timeout.
5. A PS error report ("io error") is
sometimes printed out during data
communication with the NIB when using
AppleTalk from a Mac terminal.
Change in Specification:
The word "Emulation" was changed to
"Printer Language" in the listed information
displayed by the info command.
Firmware modified to correct the following.
1.
When 80000000(H) or higher is
registered in the Manager IPX Address
2 in the Web Status Monitor, the setting
registered is changed to an unspecified
one.
2.
The NIB stops printing if several print
jobs are continuously sent to the NIB via
the IPP port (SmartNetMonitor for
Client), and a print job sent via the
standard IPP port may be canceled.
3.
The USTATUS data may sometimes be
lost, depending on the timing of when it
is sent during bi-directional
communication over TCP/IP port 9100.
4.
IP address 0.0.0.0 can be set by the
ifconfig command.
5.
The spelling of the message for saving
data at logoff was corrected from
"datas" to "data".
Change in Specification:
The length of the ID display for the prnlog
command (telnet, rsh, and ftp) was changed
from 2 digits to 10 digits.
SM
5,9 ENGINE FIRMWARE HISTORY
FIRMWARE
SERIAL
LEVEL
NUMBER
G0585910 D
February 2000
production
April 2000
G0585910 E
production
5-21
FIRMWARE
VERSION
1.49
1.51
G056/G058