Service Maintenance - Gestetner G056 Service Manual

Table of Contents

Advertisement

SERVICE MAINTENANCE

2.2 SERVICE MAINTENANCE
The following tables list the PM items when the PM is done by service.
NOTE: 1) You must switch on meter-charge mode in printer engine service mode
to disable the user's PM warning.
2) After replacing the fusing unit, make sure to reset the PM counter using
the printer engine service mode "PM Counter Reset".
Symbol key: C: Clean, R: Replace, L: Lubricate, I: Inspect
Main unit
Item
Paper Feed
Paper Feed Roller
Friction Pad
Registration Mylar
Around the Drum
Transfer Roller
Fusing Unit and Paper Exit
Hot Roller
Pressure Roller
Hot Roller Strippers
Fusing Thermistor
Bushing - Fusing Roller
Bushing - Fusing Pressure
Fusing Entrance and Exit Guide
Plates
Paper Tray Unit
Paper Feed Roller
Friction Pad
Bottom Plate Pad
Four-bin Mailbox
Exit Rollers
Driven Rollers
Trays
One-bin Shift Tray
Exit Rollers
Driven Rollers
Transport Rollers
Paper Tray
Tray Paper Sensor
G056/G058
90K
EM
R
C
Clean with water
R
C
Clean with water
C
C
Clean with water
R
R
R
R
R
C
Clean with alcohol if necessary.
R
R
Clean with water or alcohol
C
90K
EM
R
C
Clean with water
R
C
Dry cloth
C
C
Clean with water
90K
EM
C
Clean with water
C
Clean with water
C
Clean with water
90K
EM
C
Clean with water
C
Clean with water
C
Clean with water
C
Clean with water
C
Clean with water
2-2